See data in:

Wire rope isolators: 'Helical'

DEFINITION
series CB2000
  • All metal multidirectional anti-vibration/shock mounts
  • Exceptional reliability and long life
  • High damping
  • No aging
  • Corrosion resistant
  • Unequalled temperature range : -180°C to +300°C / -290F to 570 F
  • Great adaptability/versatility

Specials on request

(material size and number of loops, etc.)

Dimensions are in milimeters. For reference only

Series

Materials and finishes
(meets RoHS requirements)

CB2000

Cable:
stainless steel
galvanized available: CBG
Retainer bars:
aluminium alloy/
SurTec
Screws:
alloy steel/ zinc plate
Inserts:
stainless steel

All stainless steel: CBSS

Other materials on request
Model

height

H (mm)

width

W (mm)

weight

(kg)

-10
180
210
22,2
-12
216
248
26,3
-15
235
270
28,5
Interfaces

fixtures holes D

Bar 2
Bar 1
4 through holes ø20mm
4 through holes ø20mm counter-sunk 90°
4 inserts M18
4 through holes ø20mm
no suffix
not standard
not standard
4 through holes ø20mm counter-sunk 90°
CM
CM2
not standard
4 inserts M18
IM
CIM
IM2
C
B
2
0
0
0

Serie: CB2000

'Helical' mount from the CB2000 series

-
1
0

Model: -10

height: 180mm
width: 210mm
weight: 22,2kg
loops: serie standard is 08 loops

C
I
M

Interface: CIM

4 through holes ø20mm counter-sunk 90° in bar 1,
4 inserts M18 in bar 2

Wire rope isolators: 'Helical'

PERFORMANCE DATA
series CB2000

Compression and tension

CB2000 Series
Model
-10
-12
-15
1. Max Static
F daN
3020
2154
1808
d mm
12,6
18,6
21,8
2. Max Shock
F daN
9062
6462
5425
d mm
68
100
117
3. Max Vibration
2a mm
7,5
11,1
13
f Hz
5,6
4,6
4,2
1. Max Static
F daN
3020
2154
1808
d mm
10,1
14
16,3
2. Max Shock
F daN
31911
21522
17963
d mm
46
60
70
3. Max Vibration
2a mm
5,1
6,7
7,7
f Hz
7,2
6,2
5,7

Compression/roll 45° - Tension/roll 45°

CB2000 Series
Model
-10
-12
-15
1. Max Static
F daN
2265
1615
1356
d mm
18,4
23,1
27,2
2. Max Shock
F daN
5983
4222
3541
d mm
102
151
176
3. Max Vibration
2a mm
11,3
16,6
19,4
f Hz
4,1
3,5
3,2
1. Max Static
F daN
2265
1615
1356
d mm
13
18,5
21,2
2. Max Shock
F daN
15916
10697
8925
d mm
52
69
80
3. Max Vibration
2a mm
5,8
7,6
8,8
f Hz
5,8
5
4,7

Shear or Roll

CB2000 Series
Model
-10
-12
-15
1. Max Static
F daN
1510
1077
904
d mm
14,7
24,3
27,6
2. Max Shock
F daN
8955
5695
4661
d mm
67
93
109
3. Max Vibration
2a mm
7,4
10,3
12
f Hz
2
1,8
1,7
  1. Max static load (F) with corresponding deflection (d)
  2. Max shock load (F) with corresponding deflection (d)
  3. Uncoupled resonant frequency (f) under max static loading 1. and max peak to peak sinusoidal vibration input (2a)

*IMPORTANT: Performance characteristics are given here for reference only. They can be increased under specific conditions. Contact us

Typical shock/vibration specifications:

Air AIR 7306, MIL-E-5400, MIL-C-172, MIL-STD-810
Ground Forces GAM EG13A, SEFT 001, MIL-STD-810, VG 9533
Marine GAM EG13C, IT25-21/96-31/15-86, MIL-S-167, MIL-S-901, STANAG 042, BV 043.73, BV 044
Others GAM EMB1, GAM EMBT4, DEF STAN 07-55, IEC 571, FINABEL 2C